Free Nutanix NCS-Core Practice Exam with Questions & Answers | Set: 2

Questions 11

Refer to the exhibits.

An administrator has reported that a new VM is not performing well.

NCS-Core Question 11

NCS-Core Question 11

After analyzing the information presented in the exhibits, which option shows the best conclusion regarding this workload?

Options:
A.

VM is CPU constrained since the hypervisor cannot provide the required resources.

B.

VM is CPU constrained because more CPU needs to be added to the VM.

C.

VM is Storage constrained, because the workload is waiting for storage access.

D.

VM is not CPU constrained, because the VM is not running, a multithreaded application.

Nutanix NCS-Core Premium Access
Questions 12

Which Nutanix feature creation is described in the Knowledge Transfer?

Options:
A.

Calm Blueprints

B.

REST API

C.

Self Service Portal

D.

Data Protection Domain

Questions 13

During an AHV upgrade, a database VM automatically migrated to another host. A customer is concerned about potential storage performance impact.

Which statement addresses the customer's concern?

Options:
A.

Shadow clones mitigate the need for data locality.

B.

Data locality is not required on all flash nodes.

C.

Mirroring the database on two VMs eliminates the need for data locality.

D.

AHV's built in scheduler automatically restores data locality.

Questions 14

After the migration, some SQL queries take longer to execute than prior to migration.

The following SQL best practices were applied while creating the SQL VM on Nutanix:

•8 vDisks per SQL server VM

•Database and Log files on separate vDisk

•2 TempDB database drives and 1 TempDB log drive

What should the administrator to do improve the SQL Server performance?

Options:
A.

Redistribute existing data by creating additional database file and enable autogrowth

B.

Create multiple TempDB data files and enable autogrowth

C.

Create multiple SQL log files and disable autogrowth

D.

Redistribute existing data by creating additional database files and disable autogrowth

Questions 15

Which Nutanix tool does the Field Installation Guide provide instructions for?

Options:
A.

Prism Central

B.

Foundation

C.

As-Built Generator

D.

Nutanix Move

Questions 16

Refer to the exhibit.

NCS-Core Question 16

A Nutanix host is connected as shown in the exhibit with br0-up set to active/backup. Physical Switch 1 experiences a power outage causing br0-up to failover to using eth2. The CVM and host become inaccessible. User VMs restart on other hosts in the cluster, which causes a disruption to those VMs.

Which configuration issue likely caused this outage?

Options:
A.

Bridge br0-up should be configured to use balance-tcp rather than active/backup.

B.

The CVM should have eth1 connected to the OVS.

C.

The upstream port for eth2 is missing a VLAN.

D.

The user VMs only have one NIC

Questions 17

An administrator is performing a set of routine checks and notes that Prism Central is running with 4 vCPUs and 21 GB RAM. The organizations environment is based on two Nutanix clusters with 170 VMs plus a Legacy vSphere infrastructure. No manual changes have been done on Prism Central VM.

Which configuration justifies the current Prism Central configuration?

Options:
A.

Nutanix Move is running on Prism Central to import VMs from the Legacy Cluster.

B.

Prism Central was installed for Large Deployment environments.

C.

Prism Central is running on the legacy duster and requires more RAM.

D.

Nutanix Leap and Nutanix Flow have been enabled on Prism Central

Questions 18

A customer with a four-node RF2 cluster is adding application VMs to their system. After adding these VMs, the Prism dashboard shows 81% storage utilization.

What is the consequence of running the cluster at 81% storage utilization?

Options:
A.

The customer has the ability to add more VMs up to the 100% storage utilization.

B.

There is available capacity in the storage fabric and the cluster is resilient.

C.

Node failure is imminent due to storage utilization.

D.

The cluster is not resilient in the storage fabric

Questions 19

An administrator is supporting a business critical environment and deploys metro availability to achieve a zero data loss configuration. The two clusters are connected by a 1GbE connection. A new workload is going to be deployed to this cluster. This workload requires a sustained 150MB/S of write throughput and 20MB/s of read throughput.

Which change must be made to deploy the workload successfully on this cluster?

Options:
A.

The bandwidth must be increased to support this workload.

B.

The workload must be configured to read at greater than 12.5MB/S.

C.

The replication frequency must be less than 60 minutes.

D.

Zero data loss nearsync must be used to support this workload.

Questions 20

A consultant finishes creating a new ESXi cluster. The consultant connects to the nodes via laptop and a personal flat switch. The host/CVM network is on VLAN 23. The customer has the native VLAN on the ToR switches set to 23.

The customer wants to use LACP. Before placing the nodes on the customer network, the consultant tags VLAN 23 for each host and CVM. The consultant connects the nodes to the customer network and finds that they are unreachable.

What is causing this issue?

Options:
A.

The customer has LACP fallback enabled on switch ports.

B.

The hosts have not been migrated to a vSphere Distributed Switch.

C.

Under the vSwitch0 settings, the consultant did not select Route based on IP hash.

D.

The host and CVM are incorrectly configured.

Exam Code: NCS-Core
Certification Provider: Nutanix
Exam Name: Nutanix Certified Services Core Infrastructure Professional
Last Update: Jul 20, 2025
Questions: 309