Free Cisco 300-615 Practice Exam with Questions & Answers | Set: 6

Questions 51

An engineer troubleshoots a VXLAN EVPN data center. The applications in the data center fail to reach the DNS server that is located at IP 10.10.10.10. The engineer examines the BGP EVPN routing table and notes that the IP prefix route covers the DNS server is missing. Which action resolve the issue?

Options:
A.

Set the IP prefix route to represent [5]:[0] :[0]:[32] :[10.10.10.10]/224 in the routing table.

B.

Configure an IP ARP entry to represent [2]:[0] :[0]:[48] :[0050.569f.1285]:[32] :[10.10.10.10]/272 in the routing table

C.

Set the IP prefix route to represent [2]:[0] :[0]:[48] :[0050.569f.1285]:[0] :[0.0.0.0]/216 in the routing table

D.

Configure an IP ARP entry to represent [4]:[0300.0000.00fc.bd00.0309l[32] :[10.10.10.10]/136,n the routing table

Cisco 300-615 Premium Access
Questions 52

Refer to the exhibit.

300-615 Question 52

The vPC neighborship between two switches is in suspended state. Which configuration change resolves the issue and brings up the vPC neighborship?

Options:
A.

Change STP Port Type to Network on the peer switch

B.

Enable Bridge Assurance on the local switches

C.

Configure QoS MTU value of 9216 on the peer switch

D.

Add VLAN 400-401 to the configuration on the local switch

Questions 53

The Cisco UCS Manager fails to integrate with Cisco Intersight. The requirement is to monitor and configure the UCS environment from UCS Manager as well as Cisco Intersight. However, Cisco Intersight can monitor only the managed devices. Which action resolves the issue?

Options:
A.

Set the Access Mode of Intersight Connector on the UCS to Allow Control.

B.

Allow Cisco IMC IP addresses of all the managed servers to reach Cisco Intersight.

C.

Update the NTP settings on all the devices that Intersight manages to be in the same time zone.

D.

Change the configured DNS server to resolve the Cisco Intersight IP address.

Questions 54

Refer to the exhibit.

300-615 Question 54

The integration between Cisco UCS Manager and Cisco UCS Central failed. Which action resolves the issue?

Options:
A.

Implement the consistent NTP source between the appliances

B.

Implement the connectivity between the appliances through a firewall

C.

Configure the certificate between the appliances

D.

Configure the shared secret key between the appliances

Questions 55

Refer to the exhibit.

300-615 Question 55

A network engineer is implementing a pair of Cisco Nexus 9000 Series Switches. During the OSPF configuration, the engineer discovers unstable routing in the network. The investigation shows flapping routes after the new switches were introduced. Which set of actions resolves the issue?

Options:
A.

Configure a new IP address on the Ethernet interface toward the OSPF neighbor. Clear the OSPF neighbor.

B.

Configure a new IP address on the Ethernet interface toward the OSPF neighbor. Clear the OSPF process.

C.

Configure a new OSPF priority on the Ethernet interface toward the OSPF neighbor. Clear the OSPF neighbor.

D.

Configure a new IP address on the Loopback interface for the OSPF process. Clear the OSPF process

Questions 56

One of Cisco Nexus Series interfaces has become errdisabled with the error message “DCX-No ACK in 100 PDUs”. What is the cause of this error?

Options:
A.

The host has not responded to the Control Sub-TLV DCBX exchanges of the switch.

B.

The acknowledgement number in the server response has not incremented for 100 exchanges.

C.

Cisco Discovery Protocol is disabled on the switch.

D.

LLDP is disabled on the switch.

Questions 57

Refer to the exhibit.

300-615 Question 57

An engineer fails to load the Cisco Nexus 9000 Series Switch to configuration mode. Which command set resolves the issue?

Options:
A.

Loader > boot bootflash:bootflash_sync_list

switch(config)# boot nxos bootflash:nxos.7.0.3.I7.8.bin

switch(config)# copy run start

B.

Loader > boot nxos.7.0.3.I7.8.bin

switch(config)# boot nxos bootflash:bootflash_sync_list

switch(config)# copy run start

C.

Loader > boot nxos.7.0.3.I7.8.bin

switch(config)# boot nxos bootflash:nxos.7.0.3.I7.8.bin

switch(config)# copy run start

D.

Loader > boot nxos.7.0.3.I7.8.bin

switch(config)# boot bootflash:nxos.7.0.3.I7.8.bin

switch(config)# copy run start

Questions 58

Cisco Unified Computing System Manager raises a critical error message that indicates that the system has overlapping Ethernet and FCoE VLANs. All of the Ethernet traffic on the overlapping VLANs drops. Which action resolves the issue?

Options:
A.

Modify the VLAN assignment to vNICs.

B.

Change the PIN groups on the vHBAs.

C.

Modify the FCoE VLAN.

D.

Set the FCoE VLAN as the native VLAN on server uplinks.

Questions 59

Refer to the exhibit.

300-615 Question 59

An OSPF adjacency between Router-A and Router-B cannot reach the FULL state. Which action resolves the issue?

Options:
A.

Adjust the MTU on Router-A to 1600.

B.

Disable the check of the MTU value.

C.

Set the OSPF media type to point-to-point.

D.

Adjust the MTU on Router-B to 1604.

Questions 60

Refer to the exhibit.

300-615 Question 60

The VXLAN communication fails between Server A and Server C. Server A and Server B can communicate, but Server C can only reach Server B and its default gateway. Which action must be taken on Leaf-3 to resolve the issue?

Options:
A.

Configure a tenant Layer 3 VNI.

B.

Implement a VLAN 110 Layer 3 VNI.

C.

Configure a Layer 2 VNI.

D.

Implement a VLAN 120 Layer 2 VNI.

Exam Code: 300-615
Certification Provider: Cisco
Exam Name: Troubleshooting Cisco Data Center Infrastructure (300-615 DCIT) v1.1
Last Update: May 23, 2026
Questions: 221