A Fibre Channel interface on a Cisco Nexus 5000 Series Switch receives bit errors, and the switch disables the interface. A temporary workaround must be implemented before the root cause is identified. Which action does an engineer take to prevent this issue from reoccurring?
Refer to the exhibit.
The EEM script fails to send an SNMP trap when a user attempts to enter configuration mode. Which configuration is missing from the script?
NO: 80
Refer to the exhibit. During a maintenance window of the Nexus switch pair, one of the Cisco Nexus chassis was brought offline for maintenance. The primary Cisco Nexus switch was stable during the maintenance window. After finishing the
tasks on the chassis, the administrator wanted to bring the second switch online. The administrator checked the status of the disconnected switch that was removed from the vPC during the maintenance. The engineer must connect the peer chassis seamlessly with the primary vPC peer without experiencing traffic interruption. Which action accomplishes this goal?
An engineer is troubleshooting a failed DCBX exchange between a server and a Cisco Nexus switch. Which action allows DCBX to successfully negotiate?
Refer to the exhibit.
The initiator that has FC ID 0x970102 fails to communicate with the target that has FC ID 0x970200. What action resolves the issue?
A network engineer notices a sudden interruption to the HSRP adjacency between the switches. The packet loss is reported on the servers for which the default gateway is set as the virtual IP of the HSRP. AII servers on
the VL AN can exchange ping messages. Which configuration set must be applied on the HSRP peers to resolve the adjacency issue?
Refer to the exhibit.
An engineer is performing a health check on ACI. Which statement about interface Ethernet 1/11 is true?
The Cisco Nexus switch is connected to a peer switch that is not running Cisco NX-OS. The switches are connected using port channel and are experiencing packet loss. Which action should be performed on the Cisco Nexus switch ports to resolve this issue?
A network engineer experiences the error “DDR3_P1_B1_ECC” when upgrading Cisco UCS firmware. Which action resolves the issue?
What does this adapter output indicate?
adapter 1/6/1 (fls): 2# lunlist 9
vnic: 9 lifid: 6
- FLOGI State : flogi est (fc_id Oxac0e04)
- PLOGI Sessions
- WWNN 50:0a:09:83:8d:53:43:44 WWPN 50:0a:09:83:8d:53:43:44 fc_id 0x000000
- LUN's configured (SCSI Type, Version, Vendor, Serial No.)
- LUN ID: Ox0000000000000000 access failure
-REPORT LUNs Query Response
- Nameserver Query Response
-WWPN: 54:b1:6a:94:64:3e:73:44