Spring Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 70track

Free Pure Storage FlashArray-Implementation-Specialist Practice Exam with Questions & Answers | Set: 3

Questions 21

If a Technical Support Engineer (TSE) is not available to perform health checks after an installation, what action should the Implementation Engineer take?

Options:
A.

Email the account team

B.

Update and close the case.

C.

Verify that Remote Assist (RA) is open and update the case.

Pure Storage FlashArray-Implementation-Specialist Premium Access
Questions 22

An Implementation Engineer arrives on site to complete a shelf evac. What action must take place before Pure Support can run the completion commands?

Options:
A.

Set maintenance tag.

B.

Power off the shelf.

C.

Enable Remote Assist (RA).

D.

Disconnect the SAS or NVMe cables.

Questions 23

On a FlashArray//XR4, which port is enabled for the management service by default?

Options:
A.

ETH0

B.

ETH2

C.

ETH4

D.

ETH6

Questions 24

An Implementation Engineer has installed a data pack and the puredrive list command shows the drives in "unadmitted" status.

Which command should the Implementation Engineer run to complete the admission?

Options:
A.

puredrive admit

B.

puredrive add

C.

purearray drive admit

D.

purehw drive admit

Questions 25

A FlashArray arrives with Purity 5.3.8 applied out of the factory. The account team requests that the array be configured with Purity 6.1.21. Which steps should the Implementation Engineer select to meet this requirement?

Options:
A.

Create a bootable USB stick from the 6.1.21 ISO file and reimage both controllers with it.

B.

Copy the PPKG and SHA1 files to a USB stick and upgrade the controllers.

C.

Configure the array with the current code and then open a case with Support to upgrade.

Questions 26

What command should the Implementation Engineer run to view NVRAM install and update status?

Options:
A.

puredrive list

B.

purehw list --all

C.

purearray list

D.

purefw list

Questions 27

An Implementation Engineer is onsite to add a new 91TB (10 x 9.1TB) data pack to a FlashArray that includes a DirectFlash Shelf. The chassis currently contains two write groups, one 45TB (10 x 4.5TB) and one 91TB (10 x 9.1TB). The shelf contains a single 45TB (10 x 4.5TB) write group. The customer requests that the new data pack be added as part of a wide write group. How should the Implementation Engineer meet this request?

Options:
A.

Have support set a tunable to allow the wide write group to extend between the chassis and shelf; then add the drives to the shelf to extend the write group from the chassis.

B.

Add the drives to the shelf and then run puredrive admit --wide-write-group to admit them into the same write group in the shelf.

C.

Move the chassis write group of 45TB (10x4.5TB) to the shelf and then add the new data pack to the chassis.

Questions 28

Which Purity command can be used to validate I/O is balanced across initiators?

Options:
A.

purehost list --balance

B.

purehost iobalance --check

C.

purehost monitor --balance

Questions 29

On a FlashArray//XR20R2/3 Fibre Channel (FC) array, what is the default type and placement of the PCIe FC card?

Options:
A.

2-port in slot 0

B.

2-port in slot 2

C.

4-port in slot 0

Questions 30

Upon completion of a hardware upgrade activity, which command should be used to unset the maintenance tag?

Options:
A.

purealert tag --cancel

B.

purealert untag --maintenance

C.

purealert --unset