Summer Special 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: bestdeal

Free VMware 5V0-21.21 Practice Exam with Questions & Answers | Set: 2

Questions 11

An administrator is tasked with setting up Kerberos authentication only for the vSAN File services.

Which version of Kerberos must be selected if the NFS version is v4.1?

Options:
A.

krb5i

B.

krb4

C.

krb5

D.

krb5p

VMware 5V0-21.21 Premium Access
Questions 12

An administrator is setting up vSAN file services on a vSAN cluster.

Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)

Options:
A.

Forged Transmits

B.

Promiscuous Mode

C.

DVFiltering

D.

Jumbo Frames

E.

MacLearning

Questions 13

A 30-minute power maintenance window has been approved on Sunday. Due to a delay, the maintenance took 20 minutes longer to finish.

During this time, the vSAN administrator noticed that one of the clusters nodes was affected by a power shortage, as it was connected to an affected power source. The default vSAN storage policy has been applied.

What will be the status of the vSAN objects on the affected host immediately after it is recovered?

Options:
A.

The cluster will be partitioned and the vSAN host will need to be rejoined.

B.

A rebuild of the affected objects will occur.

C.

All objects will remain accessible.

D.

All objects on the affected host will be lost.

Questions 14

An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.

The company also has the following:

* An iSCSI array of 300TB. which runs at 76% of its capacity

* A NAS system of 200TB, which runs at 10% of its capacity

* A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity

The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.

Which storage option will work for this use case?

Options:
A.

Create an HCI Mesh using the first cluster’s datastore.

B.

Obtain additional free capacity from the existing NAS storage.

C.

Obtain additional free capacity from the existing FC storage.

D.

Create an HCI Mesh using the second cluster’s datastore.

Questions 15

An administrator has noticed that a number of the virtual machines in the preferred site are showing as either failed or partitioned.

In which two ways would the administrator expect the virtual machines to respond? (Choose two.)

Options:
A.

They will be disconnected.

B.

They will be restarted in the secondary site.

C.

They will be restarted at the preferred site.

D.

They will be powered off.

E.

They will be removed from inventory.

Questions 16

An architect is reviewing a vSAN cluster that has an unbalanced cluster configuration.

Which behavior will the architect observe?

Options:
A.

Consistent maintenance procedures

B.

Reduced predictability of storage performance

C.

Reduced deduplication capabilities

D.

Faster rebuild times

Questions 17

An administrator has been tasked with enabling encryption for existing virtual machines on a vSAN cluster.

Which three prerequisites must be satisfied before completing the task? (Choose three.)

Options:
A.

Create an encryption storage policy

B.

Enable Data-In-Transit encryption first

C.

Enable that the virtual machines are powered on

D.

Verify if a role with privilege “Cryptographic operations.Encrypt new” is assigned

E.

Verify if a role with privilege “Cryptographic operations.Migrate” is assigned

F.

Establish a trusted connection with the KMS

Questions 18

An architect is working with vSAN and setting the fault domains to support FTT=1.

How many fault domains will be needed?

Options:
A.

2

B.

3

C.

4

D.

1

Questions 19

Due to the success of the recently deployed developer-only private cloud solution, a company has a new requirement to at least double the usable capacity in their all-flash vSAN cluster.

The vSAN cluster is deployed into a co-located datacenter that is owned by a third-party hosting company. The hosting company charges a fixed monthly cost for rack space and power consumption. The service owner has been given a limited budget for additional hardware purchases, but not for on-going co-location costs.

The current vSAN cluster has the following configuration:

* 10 vSAN Nodes with 2 CPUs (20 cores), 512 GB RAM

* 1 Disk Group per vSAN node

- 1 x 400 GB

- 4 x 1.8 TB

* De-duplication and Compression is enabled.

* vSAN Capacity is currently:

- Total: 72 TB

- Usable: ~40 TB (FTT1/RAID1) and ~60 TB (FTT1/RAID5).

As a result of any action taken, the service owner would like to ensure that overall availability of the vSAN cluster is increased.

Which two recommendations meet the requirement to increase capacity while maintaining service availability? (Choose two.)

Options:
A.

Install an additional 400 GB SSD and 4 x 1.8 TB SSDs per vSAN node.

B.

Update the existing Disk Group, and claim the newly installed drives for each node.

C.

Create a new Disk Group, and claim the newly installed cache and capacity SSD drives for each node.

D.

Install an additional 3 x 1.8 TB SSDs per vSAN node.

E.

Replace existing SSDs with an 800 GB SSD and 4 x 3.8 TB SSDs per vSAN node.