Weekend Special Sale 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: sale75best

Free Netapp NS0-094 Practice Exam with Questions & Answers | Set: 2

Questions 11

In which two sections of AutoSupport can you find information to analyze the following panic? (Choose two.)

Panic_Message: PCI Error NMI from device(s):ErrSrcID(CorrSrc(0xf00),UCorrSrc(0x18)), RPT(0,3,0):Qlogic FC 16G adapter in slot 1 on Controller

Options:
A.

HA-RASTRACE.TGZ

B.

ALL-COREDUMP.XML

C.

SSRAM-LOG

D.

PCI-HIERARCHY.XML

Netapp NS0-094 Premium Access
Questions 12

You notice the following system alert during a routine check of a four-node NetApp ONTAP cluster:

Alert ID: SwitchIfDead_Alert

Resource: Slot: 0 Port: 55 100G - Level

Severity: Major

Probable Cause:

The interface broadcomswitch-011/Slot: 0

Port: 55 100G - Level is up, but it is

not passing unicast traffic.

Possible Effect:

The lack of transmit or receive traffic

reported by the switch can indicate

issues with port-level or switch-level

data packet forwarding.

Corrective Actions:

1) Check interface counters and neighbor

discovery information to verify the

port's activity.

2) Check cluster and switch health status.

The customer confirms that the cables are connected correctly and interface LEDs on the switches are on.

What is the next step in troubleshooting this issue?

Options:
A.

Remove the cluster ports from the cluster IPspace and cluster broadcast domain, and delete the health alerts.

B.

Verify the configuration of the switchports with the output of RCF Configurator.

C.

Bounce the cluster interconnect ports on the ONTAP cluster nodes that are reporting this alert.

D.

Revert the ONTAP software upgrade to see if the alert disappears.

Questions 13

Which three commands can be used to manually generate a kernel core file? (Choose three.)

Options:
A.

SP > system power cycle

B.

:: > reboot –node < node_name > –dump true

C.

:: > halt –dump true –node < node_name >

D.

:: > system node panic –node < node_name >

E.

SP > system core

Questions 14

Which two scenarios are common causes of the root volume needing root volume recovery? (Choose two.)

Options:
A.

The root volume ran out of space.

B.

The mainboard was replaced following a Non-Maskable Interrupt (NMI) panic.

C.

Root volume migrate was performed.

D.

The cluster configuration is out of sync on the volume.

Questions 15

What are the two steps to unfail a disk in maintenance mode? (Choose two.)

Options:
A.

Reseat the disk.

B.

Remove it from the Failed Disk Registry.

C.

Use the "disk unfair command.

D.

Use the disk remove command.

Questions 16

On an AFF A700 system, a SAS stack is connected to SAS ports 2a and 2b. The system has an additional 4-port SAS card in slot 9.

How should the cabling the corrected for best practices?

Options:
A.

Use port 2a and 9a.

B.

Use port 2a and 9b.

C.

Use port 2a and 2c.

D.

Use port 2b and 9d.

Questions 17

You are upgrading your 6-node NetApp ONTAP cluster from ONTAP 9.9.1 to 9.16.1. As part of the ONTAP software upgrade process, you need to update the cluster switches. After you update the first switch, you receive the following AutoSupport message:

Exhibit — AutoSupport Alert

vifmgr: callhome.clus.net.degraded:alert:

Call home for CLUSTER NETWORK DEGRADED:

Large MTU Packet Loss - Ping failures detected

between Node1_clus1 (169.254.2.94) on Node1

and Node2_clus2 (169.254.248.67) on Node2.

All cluster ports and interfaces are in an up/up status.

What is causing this error?

Options:
A.

ONTAP software is not at the same version on all nodes.

B.

The RCF file has not been applied to all switches.

C.

The ONTAP software version is not compatible with some of the controllers.

D.

The cluster switches have different firmware versions.

Questions 18

You have replaced a failed boot device. You perform boot_recovery and receive no errors. However, when the node reboots, it reports that it has no disks.

What are two possible causes? (Choose two.)

Options:
A.

The SAS cables were incorrectly reconnected after reinstalling the motherboard.

B.

The disks that are owned by this node have been marked as failed.

C.

The node is booting a lower version of ONTAP software than was last used.

D.

The interconnect is down.

Questions 19

You have created a case with NetApp Support for an issue with a DS4246 shelf on an ONTAP 9.12.1 system. They have requested that you provide shelf logs.

What action do you need to take to collect the shelf logs?

Options:
A.

Provide the output of the nodeshell command rdfile/etc/log/shelflog.

B.

Invoke an autosupport of type all using Active IQ Unified Manager.

C.

Invoke a diagnostic AutoSupport with the subsystem storage.

D.

Invoke a diagnostic autosupport with the subsystem log_files.

Questions 20

Following an unexpected takeover, the taken-over node is waiting for giveback. The administrator plans to perform a giveback with the option –cfo–only true.

What happens if this option is used?

Options:
A.

Only a simulation of the giveback is performed.

B.

Only the root aggregate is given back.

C.

Only SVM root volumes are sent back

D.

Only the data aggregates are sent back.

Exam Code: NS0-094
Certification Provider: Netapp
Exam Name: NetApp Hardware Support Engineer Professional Exam
Last Update: Nov 20, 2026
Questions: 81
PDF + Testing Engine
$169.99
$42.5
Testing Engine
$129.99
$32.5
PDF (Q&A)
$104.99
$26.25