In which two sections of AutoSupport can you find information to analyze the following panic? (Choose two.)
Panic_Message: PCI Error NMI from device(s):ErrSrcID(CorrSrc(0xf00),UCorrSrc(0x18)), RPT(0,3,0):Qlogic FC 16G adapter in slot 1 on Controller
You notice the following system alert during a routine check of a four-node NetApp ONTAP cluster:
Alert ID: SwitchIfDead_Alert
Resource: Slot: 0 Port: 55 100G - Level
Severity: Major
Probable Cause:
The interface broadcomswitch-011/Slot: 0
Port: 55 100G - Level is up, but it is
not passing unicast traffic.
Possible Effect:
The lack of transmit or receive traffic
reported by the switch can indicate
issues with port-level or switch-level
data packet forwarding.
Corrective Actions:
1) Check interface counters and neighbor
discovery information to verify the
port's activity.
2) Check cluster and switch health status.
The customer confirms that the cables are connected correctly and interface LEDs on the switches are on.
What is the next step in troubleshooting this issue?
Which three commands can be used to manually generate a kernel core file? (Choose three.)
Which two scenarios are common causes of the root volume needing root volume recovery? (Choose two.)
What are the two steps to unfail a disk in maintenance mode? (Choose two.)
On an AFF A700 system, a SAS stack is connected to SAS ports 2a and 2b. The system has an additional 4-port SAS card in slot 9.
How should the cabling the corrected for best practices?
You are upgrading your 6-node NetApp ONTAP cluster from ONTAP 9.9.1 to 9.16.1. As part of the ONTAP software upgrade process, you need to update the cluster switches. After you update the first switch, you receive the following AutoSupport message:
Exhibit — AutoSupport Alert
vifmgr: callhome.clus.net.degraded:alert:
Call home for CLUSTER NETWORK DEGRADED:
Large MTU Packet Loss - Ping failures detected
between Node1_clus1 (169.254.2.94) on Node1
and Node2_clus2 (169.254.248.67) on Node2.
All cluster ports and interfaces are in an up/up status.
What is causing this error?
You have replaced a failed boot device. You perform boot_recovery and receive no errors. However, when the node reboots, it reports that it has no disks.
What are two possible causes? (Choose two.)
You have created a case with NetApp Support for an issue with a DS4246 shelf on an ONTAP 9.12.1 system. They have requested that you provide shelf logs.
What action do you need to take to collect the shelf logs?
Following an unexpected takeover, the taken-over node is waiting for giveback. The administrator plans to perform a giveback with the option –cfo–only true.
What happens if this option is used?
|
PDF + Testing Engine
|
|---|
|
$42.5 |
|
Testing Engine
|
|---|
|
$32.5 |
|
PDF (Q&A)
|
|---|
|
$26.25 |
Netapp Free Exams |
|---|
|