Weekend Special Sale 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: sale75best

Free Netapp NS0-094 Practice Exam with Questions & Answers | Set: 3

Questions 21

You are replacing a boot device on a FAS8300 system that is running ONTAP 9.10P6 software. You attach a USB memory stick to the external USB port on the storage controller but cannot access the memory stick.

What step needs to be performed to access the boot device?

Options:
A.

Set the port to “enabled” with setenv.

B.

You need to use ONTAP 9.11 or later software.

C.

Add the boot device before the BIOS is loaded.

D.

The external USB port is not activated on NetApp systems.

Netapp NS0-094 Premium Access
Questions 22

Your customer notices that their AFF A220 high-availability (HA) system is showing Single-Path HA.

NS0-094 Question 22

How do you make the system into multipath HA?

Options:
A.

0a and 0b on both controllers should be connected.

B.

0a and 0c on both controllers should be connected.

C.

0c and 0d on both controllers should be connected.

D.

0a and 0d on both controllers should be connected

Questions 23

Which of the following scenarios could result in a NetApp WAFL inconsistency in a RAID DP aggregate?

Options:
A.

two disks failing and a block error during reconstruction

B.

rebooting a node during a disk reconstruction

C.

two disks failing within seconds of each other

D.

both party disks failing

Questions 24

You receive the following AutoSupport message:

[Node-01: cshmd: hm.alert.raised:alert]:

Alert Id = ClusterSwitchConnectivity_Alert

Alerting Resource = Node-02

raised by monitor ethernet-switch

[Node-01: mgwd: callhome.hm.alert.major:alert]:

Call home for Health Monitor process cshm:

ClusterSwitchConnectivity_Alert[Node-02].

[Node-01: mgwd: callhome.hm.alert.major:alert]:

Call home for Health Monitor process cshm:

ClusterSwitchConnectivity_Alert[Node-02].

When researching, you discover the following output:

Exhibit 2 — Network Port Health

Cluster::* > network port show

-health-status degraded

-fields health-degraded-reasons

node port health-degraded-reasons

-------- ---- -----------------------

Node-02 e0a link_flapping

What action do you take to resolve this issue?

Options:
A.

Replace the SFP on port e0a on node-02.

B.

Update the RCF file on the cluster switches.

C.

Update the firmware on the cluster switches.

D.

Replace the SFP on port e0a on node-01.

Exam Code: NS0-094
Certification Provider: Netapp
Exam Name: NetApp Hardware Support Engineer Professional Exam
Last Update: Nov 20, 2026
Questions: 81
PDF + Testing Engine
$169.99
$42.5
Testing Engine
$129.99
$32.5
PDF (Q&A)
$104.99