Summer Special 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: bestdeal

Free Huawei H19-371_V1.0 Practice Exam with Questions & Answers | Set: 8

Questions 106

Fusion Module500 & Fusion Module800 cabinet height is 24U, 42U are optional ( ).

Options:
A.

True

B.

False

Huawei H19-371_V1.0 Premium Access
Questions 107

The static load of the FusionModule2000 cabinet can support 2400KG,

Options:
A.

True

B.

False

Questions 108

Huawei air-cooled air conditioners (35kw and 46kw) - one indoor unit corresponds to one outdoor unit ( )

Options:
A.

True

B.

False

Questions 109

The access control management function of the Netco6000 management system only supports one-way card swiping (you need to swipe your card to enter the door, and press the exit button to go out), but do not support two-way card swipe (you need to swipe your

card to enter the door and go out).

Options:
A.

True

B.

False

Questions 110

UPS5000-E (50kVA module) supports the adjustable number of battery cells to avoid the replacement of a whole battery caused by a single battery failure and solve the problem of difficult maintenance of

traditional UPS batteries. The adjustable range is 30~44 cells ( ).

Options:
A.

True

B.

False

Questions 111

FusionModule2000 sensor adopts PoE ring network power supply to improve the reliability of signal transmission in the control system, and can be used for target control.

Options:
A.

True

B.

False

Questions 112

Huawei precision air conditioners have power supply overvoltage, undervoltage alarm and fault diagnosis alarm recording functions, automatic protection, automatic recovery, automatic restart and other functions. ()

Options:
A.

True

B.

False

Questions 113

What factors are currently affecting the application of HVDC equipment in the computer room? ( )

Options:
A.

Not all loads can be directly powered by DC

B.

Higher cost of DC switching devices

C.

The efficiency is too low

D.

The standard is not perfect, and multiple standards of 240V/336V

coexist.

Questions 114

Huawei's power module FusionPower6000 has the following models/capacities (multiple choice).

Options:
A.

2.4MW

B.

1.2MW

C.

2.0MW

D.

1.6MW

Questions 115

The intelligent rPDU of Fusionmodule2000 supports C19 and C13 two specifications ( )

Options:
A.

True

B.

False

Questions 116

The integrated UPS/integrated power distribution cabinet/precision power distribution cabinet of FusionModule2000 can detect the temperature of branch terminals through NTC probes.

This function is optional and unique to Huawei.

Options:
A.

True

B.

False

Questions 117

NetCol5000-A025H half-cabinet row-level inverter air-cooled precision air conditioner, NetCol5000-A042H full-cabinet row-level air-cooled inverter precision air conditioner, NetCol8000-C 2.0 series room-level

refrigerated underwater air supply precision air conditioner adopts a 7-inch touch color screen, which can be intuitively Vivid display of unit operation information.

Options:
A.

True

B.

False

Questions 118

The UPS5000-S power module has a capacity of 50kVA and a height of 2U, the highest power density in the industry.

Options:
A.

True

B.

False

Questions 119

S5000-A Built-in Isolation Transformer

Options:
A.

True

B.

False

Questions 120

The Huawei Configurator can automatically configure the cable specifications and lengths from the head cabinet to the IT cabinet. ( ).

Options:
A.

True

B.

False