Regarding the overload capacity of UPS5000-E, which of the following statements is correct?

Options:
A.

Inverter 110% overload for 120 minutes

B.

Bypass 135% overload long-term operation

C.

Inverter 110% overload for 60 minutes

D.

Bypass 135% overload for 120 minutes

Huawei H19-371_V1.0 Premium Access
Questions 77

In a single cabinet configuration scenario, which of the following scenarios can be configured? (

Options:
A.

Fusionlodule2000

B.

FusionModule800

C.

FusionModule5000

D.

Fusionlodule500

Questions 78

The circuit breaker of ( ) pole is generally used for the external maintenance bypass of the UPS system.

Options:
A.

3

B.

1

C.

4

D.

2

Questions 79

The cooling capacity of intelligent temperature control products can only be determined when the working conditions are clarified. There are many factors that affect the cooling capacity. For example, when selecting a row-level chilled water intelligent temperature control

product, at least information such as ( ) must be specified.

Options:
A.

Return air temperature

B.

Return air humidity

C.

Inlet water temperature

D.

Return water temperature

E.

Altitude

F.

Length of connecting pipe

Questions 80

FusionModule500 uses natural heat dissipation

Options:
A.

True

B.

False

Questions 81

UPS2000-G adopts high power density design, 6k/10k is only 2U high, 15K/20K is only 3U high, reducing installation space.

Options:
A.

True

B.

False

Questions 82

FusionModule1000A V2R3 version can be customized bulletproof shell

Options:
A.

True

B.

False

Questions 83

The self-developed air-conditioning control system has a visual group control network and supports a maximum of 32 units

Options:
A.

True

B.

False

Questions 84

FusionModule1000A V2R3 version 20-foot CT solution is equipped with 4 600*800*2200mm CT cabinets

Options:
A.

True

B.

False

Questions 85

The national public security will establish three cloud computing centers at the ministry, province and city levels.

Options:
A.

True

B.

False

Questions 86

The row-level air conditioners (25kw and 42kw) of Huawei FusionModule2000 v3.0 have the refrigerant detection function. (

Options:
A.

True

B.

False

Questions 87

UPS products such as APM and NXR need to be derated when the temperature is 30 degrees, and UPS5000-E does not need to be derated when the temperature is below 40 degrees.

Options:
A.

True

B.

False

Questions 88

UPS2000-G is an online double conversion UPS. In normal working state: the mains supply energy, the rectifier converts the alternating current into direct current, and the inverter converts

the rectified direct current into pure alternating current and provides it to the load, The charger charges the battery pack ()

Options:
A.

True

B.

False

Questions 89

The operating temperature range of FusionModule800 is -20~45 degrees, and the operating temperature range of FusionModule500 is 0~45 degrees /

Options:
A.

True

B.

False

Questions 90

Huawei Netcol air-cooled air conditioner -- one indoor unit can correspond to multiple outdoor units ()

Options:
A.

True

B.

False