What does the DN in DN50 mean?

Options:
A.

The inner diameter of the tube

B.

The outer diameter of the tube

C.

Nominal Radius of Tube

D.

Nominal diameter of pipe

Huawei H19-371_V1.0 Premium Access
Questions 167

UPS2000-G-(6K-20K) maintenance bypass implementation ()

Options:
A.

Mainframe built-in maintenance bypass

B.

Optional PDU to support maintenance bypass

C.

Cannot support maintenance bypass

Questions 168

How many power modules does the FusionModule2000 integrated UPS 50K model support?

Options:
A.

2 25K modules

B.

3 25K modules

C.

2 50K modules

D.

3 50K modules

Questions 169

The UPS5000E-300K (50kVA power module) mainframe occupies a small area, saving space in the computer room, and the area is only ? ( )

Options:
A.

1 square meter

B.

1.5 square meters

C.

0.8 square meters

D.

0.5 square meters

Questions 170

Which of the following statements is false about surveillance cameras?

Options:
A.

Less than 4 cameras can be connected to the ETH socket

B.

The camera power supply mode is PoE power supply

C.

The camera can be directly connected to the switch powered by PoE

D.

Camera data can be stored through TF card or VCN500

E.

The number of cameras configured is the same as the number of control sunroofs

Questions 171

Regarding the Fusionmodule surveillance camera, which of the following statements is false? ( )

Options:
A.

Any number of cameras can be plugged into the ETH socket

B.

The camera power supply mode is PoE power supply

C.

The camera can be directly connected to the switch powered by PoE.

D.

The camera data can be stored by TF card or hard disk recorder (NVR: Network Video Recorde)

Questions 172

The UPS5000-E has the function of adjusting the number of battery cells, which avoids the failure of a single battery to cause the replacement of the entire group, and solves the problem of difficult maintenance of

traditional UPS batteries. May I ask how many cells can be adjusted in the UPS5000-E (50kVA module)? ()

Options:
A.

30-40

B.

32-40

C.

32-42

D.

30-44

Questions 173

UPS5000-A can significantly reduce the harmonic pollution to the power grid. In the case of linear full number, the input electric-hydrodynamic distortion nmi is ().

Options:
A.

0.02

B.

0.03

C.

0.05

D.

0.01

Questions 174

What is the maximum number of counters in the FusionModule2000 dual-row cabinet scenario? ( )

Options:
A.

12

B.

24

C.

36

D.

48

Questions 175

The UPS5000-E has strong load adaptability, and the capacitive/inductive load is super strong/lag () without derating.

Options:
A.

0.7

B.

0.4

C.

0.6

D.

0.5

Questions 176

What is the maximum number of cabinets in the FusionModule500& FusionModule800 modules?

Options:
A.

10, 6

B.

9,,5

C.

8, 4

D.

6, 2

Questions 177

The wrong description about the reliability of NetCol5000-C row-level air conditioner is: ().

Options:
A.

It adopts dual power supply, and the two power supply adopts automatic switching mode

B.

Large-scale data centers such as operators and large corporate headquarters are more popular with such air conditioners. .

C.

More application of SMEs Netcp15000-A air conditioner multi-fan air supply: online maintenance is possible.

D.

Cannot be used in scenarios without raised floor, because condensate drainage cannot be connected to the pipe

Questions 178

The capacity management module of the NetEco management system can manage the resource capacity information in the computer room. Which of the following capacity elements is under the management of NetEco?

Options:
A.

Network port

B.

Network Bandwidth

C.

CPU utilization

D.

None of the above is supported

Questions 179

UPS2000-G-(6K- 20K) has a strong lightning protection design in the industry, lightning protection level (), surge protection level (), can avoid 90 failures caused by lightning strikes, and reliably

protect the exchange of back-end equipment. input port.

Options:
A.

5kA; 6kV

B.

2kA; 4kV

C.

2kA; 6kV

D.

4kA; 6kV

Questions 180

The compressors selected by Huawei's 25kW half-cabinet inverter air-cooled row-level air conditioners are first-class brands in the industry, which are:

Options:
A.

Copeland

B.

Danfoss

C.

EBM

D.

DAIKIN