The asset management module of the NetEco management system supports which of the following parameters can be used to quickly search for asset information? (Multiple choice)

Options:
A.

Name

B.

Location

C.

Type

D.

Status

Huawei H19-371_V1.0 Premium Access
Questions 17

Regarding the characteristics of the FusionModule2000 row-level air conditioner, which of the following descriptions is wrong? ( )

Options:
A.

Only 42KW supports wet film humidification function

B.

Both 25KW and 42KW support wet film humidification function

C.

Both 25KW and 42KW support light-load dehumidification

function

Questions 18

When the NetCol8000-C room-level chilled water intelligent temperature control product is booted, our ( ) model will be used first.

Options:
A.

150D

B.

130D

C.

160D

D.

190D

Questions 19

Regarding the cabinet rPDU of FusionModule2000, which of the following statements is wrong?

Options:
A.

There are two kinds of half height and full height

B.

Smart rPDU supports remote monitoring and does not support remote shutdown

C.

Support C13 and C19 and national standard

socket

Questions 20

The total current of the battery pack is 1000A, and 3 sets of batteries are configured. The most economical configuration of the cable from the UPS to the main switch box is .(

Options:
A.

185mm2 (506A) × 3

B.

150mm2 (441A) x3

C.

240mm 2 (599A) x3

D.

120mm2 (382A)×3

Questions 21

In PDU8000, what are the optional functions (

Options:
A.

Input switch remote tripping function

B.

Temperature Monitoring Feature Function

C.

Branch switch hot swap function

D.

9 earthquake resistance

Questions 22

The power supply structure adopted by the new row-level half-tank chilled water is /

Options:
A.

Single power supply

B.

Dual power supply

Both C.AB are right

C.

Other

Questions 23

Configure the UPS system scheme, which of the following factors need to be considered in the calculation scheme ( )

Options:
A.

UPS type, capacity and parallel mode

B.

The brand and capacity of the battery

C.

Make and model of AC and DC cables

D.

Configuration of battery rack and battery switch box

Questions 24

Which of the following UPS does not have a neutral line ().

Options:
A.

UPS5000-H

B.

UPS5000-E

C.

galaxy5000

D.

APM150

Questions 25

UPS5000-series modular UPS product features are similar to which of the following product models? ( )

Options:
A.

Hipulse-u

B.

80-NET

C.

NXr

D.

APM

Questions 26

What is the correct function description of the intelligent micro-module iPower of Fusionllodule2000 v3.0 version?

Options:
A.

With alarm convergence function (mains power failure scenario, alarm information collection)

B.

Can monitor battery information

C.

Power Distribution Link Visualization

D.

The intelligent rPDU can monitor the electricity consumption information of each

outlet

Questions 27

When configuring temperature control products, if the temperature of the project location is -10 "30 °C, which of the following working conditions should be preferred

Options:
A.

Wide temperature (-40-55℃)

B.

T1 (-20°-45°C)

C.

T3 (-20-55℃)

D.

Ultra-low temperature (-40”45℃)

Questions 28

Which of the following tasks does the work of data center operation and maintenance include? (multiple choice)

Options:
A.

Real-time monitoring

B.

Routine Maintenance

C.

Major overhaul

D.

Emergency drills

Questions 29

FusionMoudle2000 supports the following cladding scenarios ()

Options:
A.

The column is located in the channel

B.

Column spanning aisle and column

C.

The column is located at the head or tail of the column

D.

Columns are located between columns

Questions 30

The new room-level air-cooled series is based on the indoor return air of 35C and the outdoor temperature of 35C. The cooling section has ( )

Options:
A.

45kW

B.

50kW

C.

60kW

D.

90kW

E.

100kW

F.

120kW