Questions 1

Exhaust outlets that terminate at a temperature exceeding 600°F shall be designed as a:

Options:
A.

Class I duct.

B.

Class II duct.

C.

Class III duct.

D.

single-wall metal chimney.

International Code Council M2 Premium Access
Questions 2

When a permit is issued, the code requires that one set of approved plans and specifications be returned to the applicant.

This set of plans and specifications shall be:

Options:
A.

kept on the building site.

B.

returned to the architect.

C.

filed with the county clerk or jurisdiction to properly record the property.

D.

retained by the applicant for at least one year after the job is finished in the event modifications are made.

Questions 3

Given: single-wall vent, which serves only one appliance, and has a height of 10 feet.

The maximum horizontal length permitted for a 5-inch diameter vent connector serving this vent is _____ feet.

Options:
A.

5

B.

7.5

C.

9

D.

10

Questions 4

A cooling system with a condensate disposal system:

Options:
A.

shall be made of approved corrosion-resistant material and shall not decrease in size from the drain pan connection to the place of condensate disposal.

B.

shall be made of an approved pipe and be at least 1/2-inch in diameter.

C.

shall not be less than 3/4-inch PVC pipe or equivalent approved material.

D.

shall have all horizontal sections of drain piping installed with a minimum of 1/4 inch per foot slope.

Questions 5

An equipment shutoff valve shall be in the same room and not more than how many feet away from the appliance?

Options:
A.

6

B.

7

C.

8

D.

9

Questions 6

For gas piping installations, which of the following is an acceptable joining method for polyethylene (PE) pipe?

Options:
A.

Rubber cement

B.

Solvent cement

C.

Threaded coupling

D.

Compression coupling

Questions 7

All exposed gas piping shall be kept above grade a minimum of _____ inches.

Options:
A.

3.5

B.

6

C.

8.5

D.

12

Questions 8

What is the minimum air velocity that must be provided by an exhaust duct system serving a Type I range hood?

Options:
A.

500 FPM

B.

500 CFM

C.

1,500 FPM

D.

2,500 FPM

Questions 9

Why are two or more sets of construction documents, engineering calculations, diagrams, and other data required to be submitted with each application for a permit?

Options:
A.

To ensure that the project is completed in a timely manner.

B.

All sets are to be retained by the code official in order to have a spare set of construction documents for use by any subcontractors.

C.

All sets of documents are to be kept by the code official, and at least one set will serve as a backup set of documents in case the other is lost or misplaced.

D.

One set will be retained by the code official, and the other will be returned to the applicant and kept on the job site for reference while construction is in progress.

Questions 10

Given: a six-story, sprinklered, multifamily building with a continuously ventilated shaft extending vertically from the first floor to the roof and used for exhaust.

Which of the following requirements must also be met?

Options:
A.

kitchen exhaust that penetrates the shaft without a fire damper and extends vertically 12 inches.

B.

fire dampers are installed that are connected to an emergency generator rated for 1 hour.

C.

have steel subducts with wall thickness of 0.0186 inch extending 22 inches horizontally into the shaft.

D.

kitchen exhaust that penetrates the shaft without a fire damper and extends vertically 22 inches.