Questions 1

A required standpipe shall be installed when the progress of construction above the lowest level of fire department access reaches a maximum of __ ft.

Options:
A.

30

B.

40

C.

55

D.

75

International Code Council Fire-Inspector-II Premium Access
Questions 2

What is the occupant load of a 50,000 gross square foot airport terminal concourse?

Options:
A.

200

B.

500

C.

1,000

D.

2,500

Questions 3

An acceptance test for a fire alarm system in a new apartment building should be scheduled after:

Options:
A.

each zone is completed.

B.

the contractor verifies full compliance.

C.

the hydrostatic test of the underground main is completed.

D.

the system has been installed and operating for one year.

Questions 4

A permit is required for storage of high-pile combustible stock in a building when the area of stock exceeds

Options:
A.

225

B.

500

C.

1,000

D.

2,500

Questions 5

For Halon 1211 hand-hose-line systems, all hoses for high-pressure systems must be tested at __ psi

Options:
A.

600

B.

900

C.

1,500

D.

2,500

Questions 6

A Type I handrail that is not circular shall have a minimum perimeter dimension of ___ inches.

Options:
A.

1.25

B.

2

C.

4

D.

6.25

Questions 7

The minimum fire-flow for a 75,000-sq. ft. building of Type IIB construction without a sprinkler system is:

Options:
A.

3,000 gpm for 3 hours.

B.

4,000 gpm for 4 hours.

C.

5,500 gpm for 4 hours.

D.

5,750 gpm for 4 hours.

Questions 8

Smoking is not permitted within ___ ft. of a transfer point for LP-gas while filling operations are in progress.

Options:
A.

10

B.

15

C.

25

D.

50

Questions 9

Given: In automobile refinishing spray booths where drying by heat is done in the spray booth, the spray booth shall be equipped with interlocks between the spraying and drying apparatus and the ventilating system.

These interlocks shall be arranged to purge the spray vapors from the spray booth for a minimum period of __ minutes before the drying apparatus can be operated.

Options:
A.

2

B.

3

C.

4

D.

5

Questions 10

Where requirements for fire safety are not specifically provided for by the International Fire Code, which of the following shall have the responsibility to determine the applicable requirements?

Options:
A.

City manager.

B.

Legal counsel.

C.

Board of appeals.

D.

Fire code official.