Summer Special 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: bestdeal

Free WELL WELL-AP Practice Exam with Questions & Answers | Set: 3

Questions 21

In an office building where all of the occupants are under the age of 65 years, which of the following illuminance levels meets the requirements for the office area?

Options:
A.

10 fc (110 lux) at floor level

B.

10 fc (110 lux) at task surface

C.

30 fc (320 lux) at floor level

D.

30 fc (320 lux) at task surface

WELL WELL-AP Premium Access
Questions 22

Which of the following ergonomic design strategies would a project team implement to achieve Part 1: Support Visual Ergonomics of Feature V02: Ergonomic Workstation Design?

Options:
A.

50% of workstations are height-adjustable

B.

100% of workstations include an adjustable monitor

C.

3% of employees are able to reserve a treadmill desk

D.

75% of workstation seating can be adjusted by the user

Questions 23

To contribute to Feature A11: Source Separation, which of the following rooms is most likely to require exhaust fans such that the return air is vented outdoors and not recirculated?

Options:
A.

Copy rooms

B.

Activity room

C.

Lactation room

D.

Conference rooms

Questions 24

In addition to M06: Restorative Opportunities, which feature contributes to a healthy sleep and wake rhythm?

Options:
A.

Feature M10: Tobacco Cessation

B.

Feature L03: Circadian Lighting Design

C.

Feature M08: Restorative Programming

D.

Feature V02: Ergonomic Workstation Design

Questions 25

Sick building syndrome is caused by the buildup of indoor pollutants which is linked to which of the following?

Options:
A.

Low airflow rales

B.

High filtration levels

C.

Absence of daylight

D.

Advanced building age

Questions 26

Please click on the Project Scenario B button to review the project scenario and answer the following question.

BAY TOWERS BY BAYLEAF - SEATTLE, UNITED STATES - PROJECT SCENARIO B. Bay Towers by Bayleaf is a 20-floor commercial building overlooking Elliot Bay in Seattle, United States.

The building enjoys abundant natural light through floor to ceiling windows which take in Elliot Bay city views. Although located behind a major highway (four-lanes of traffic), there is a pedestrian bridge which connects their ground floor reception to the riverfront park on the other side of the highway.

The building is owned and operated by Bayleaf Inc., a real-estate organization. The building is leased at a 70% occupancy rate by a range of tenants, including those in finance, technology and healthcare. The total expected occupancy of the building is 1,000 people.

Bay Towers is mechanically ventilated and currently has MERV 11 filters. As the building owner, Bayleaf provides HVAC fit-out for tenant spaces, but tenants complete the interior walls and supply the finishes and furniture themselves. While no food is provided by Bayleaf, some individual tenants do have pantries where they provide their own snacks and beverages for their own employees.

Bayleaf manages the building and operates the ground floor which includes the reception, building management office, meeting rooms, as well as the elevator banks on each floor and the rooftop. Meeting rooms are common amenities that are able to be booked by the tenants. Bayleaf has two employees that work at desks onsite, a receptionist at the front desk and a property manager in the building management office.

PROJECT SCOPE & GOALS

Bayleaf has enrolled Bay Towers for WELL Core Certification to attract and retain high-quality tenants and address growing tenant demand for well-being facilities.

As part of the WELL Core Certification scope, Bayleaf intends to renovate their ground floor and are open to leveraging some of this space to include health and well-being programming.

The scope of renovation will also include upgrades to the base building, such as staircases, end-of-trip facilities and the air filtration system. The rooftop will also be converted into a public green space for tenants to use for recreation. Tables, chairs and barbeque facilities will be added, as well as several gardens, including edible plots and lawn areas.

Bayleaf is hoping their WELL Core Certification will provide some initial feature compliance for tenants wishing to also pursue WELL Certification for their spaces.

By installing digital displays that promote the consumption of fruits, vegetables and water in the dedicated eating areas, which of the following features could the project team attempt?

Options:
A.

Feature N08: Mindful Eating

B.

Feature N04: Food Advertising

C.

Feature N07: Nutrition Education

D.

Feature N12: Local Food Production

Questions 27

For projects to obtain WELL Certification at the Platinum level, what is the minimum number of points that must be achieved per concept?

Options:
A.

One point

B.

Two points

C.

Three points

D.

Four points

Questions 28

A shopping center wants to comply with W08: Hygiene Support in family bathrooms. Which of the following is a strategy to achieve this feature?

Options:
A.

Touch-free exit

B.

Cleaning records

C.

Diaper dispenser

D.

Children's toilet facilities

Questions 29

For an office building with 1,500 regular occupants and 500 occasional visitors per day, which of the following facilities meets the requirements established in Feature V04: Facilities for Active Occupants?

Options:
A.

Seven showers with changing facilities and 45 lockers are available in the building

B.

Nine showers with changing facilities and 40 lockers are available in the building

C.

10 showers with changing facilities and 50 lockers are available within 500 ft. (150 m) walking distance of the project boundary

D.

12 showers with changing facilities and 50 lockers are available within 700 ft. (225 m) walking distance of the project boundary

Questions 30

An Environment, Health and Safety (EHS) manager finds that the air quality at an indoor construction site is degrading because the contractors are demolishing wooden boards. Which step should the manager take first to address this problem?

Options:
A.

Clean and seal all the ducts

B.

Use walk-off mats at entryways

C.

Use saws with dust guards or collectors

D.

Install media filters with a PM10 removal rating

Exam Code: WELL-AP
Certification Provider: WELL
Exam Name: WELL Accredited Professional (WELL AP) Exam
Last Update: Jul 15, 2025
Questions: 204

WELL Free Exams

WELL Free Exams
Unlock free WELL exam resources and practice tests at Examstrack. Boost your WELL exam readiness with top-notch materials.