An architect is designing a VMware Cloud Foundation (VCF)-based solution for a customer with the following requirement:
The solution must not have any single points of failure.
To meet this requirement, the architect has decided to incorporate physical NIC teaming for all vSphere host servers. When documenting this design decision, which consideration should the architect make?
An Architect is responsible for designing a VMware Cloud Foundation (VCF)-based solution for a customer. During the discovery workshop, the following requirements were stated by the customer:
All applications/workloads designated as business critical have a Recovery Point Objective (RPO) of 1 business hour.
The infrastructure components of the VCF solution must have a Recovery Time Objective (RTO) of 4 business hours.
In the context provided, what does the RTO measure?
During a requirement capture workshop, the customer expressed a plan to use Aria Operations Continuous Availability. The customer identified two datacenters that meet the network requirements to support Continuous Availability; however, they are unsure which of the following datacenters would be suitable for the Witness Node.
Which datacenter meets the minimum network requirements for the Witness Node?
Which Operating System (OS) is not supported by Aria Operations for OS and Application Monitoring?
A customer is deploying VCF at a new datacenter location. They will migrate their workloads from the existing datacenter to the new VCF platform over six months. Both datacenters will run simultaneously for six months during the migration. Which of the following should be a documented risk?
An architect is responsible for updating the design of a VMware Cloud Foundation solution for a pharmaceuticals customer to include the creation of a new cluster that will be used for a new research project. The applications that will be deployed as part of the new project will include a number of applications that are latency-sensitive. The customer has recently completed a right-sizing exercise using VMware Aria Operations that has resulted in a number of ESXi hosts becoming available for use. There is no additional budget for purchasing hardware. Each ESXi host is configured with:
2 CPU sockets (each with 10 cores)
512 GB RAM divided evenly between sockets
The architect has made the following design decisions with regard to the logical workload design:
The maximum supported number of vCPUs per virtual machine size will be 10.
The maximum supported amount of RAM (GB) per virtual machine will be 256.
What should the architect record as the justification for these decisions in the design document?
An administrator is documenting the design for a new VMware Cloud Foundation (VCF) solution. During discovery workshops with the customer, the following information was shared with the architect:
All users and administrators of the solution will need to be authenticated using accounts in the corporate directory service.
The solution will need to be deployed across two geographically separate locations and run in an Active/Standby configuration where supported.
The management applications deployed as part of the solution will need to be recovered to the standby location in the event of a disaster.
All management applications will need to be deployed into a management tooling zone of the network, which is separated from the corporate network zone by multiple firewalls.
The corporate directory service is deployed in the corporate zone.
There is an internal organization policy that requires each application instance (management or end user) to detail the ports that access is required on through the firewall separately.
Firewall rule requests are processed manually one application instance at a time and typically take a minimum of 8 weeks to complete.
The customer also informed the architect that the new solution needs to be deployed and ready to start the organization’s acceptance into service process within 3 months, as it is a dependency in the deployment of a business-critical application. When considering the design for the Cloud Automationand Operations products within the VCF solution, which three design decisions should the architect include based on this information? (Choose three.)
PDF + Testing Engine
|
---|
$66 |
Testing Engine
|
---|
$50 |
PDF (Q&A)
|
---|
$42 |
VMware Free Exams |
---|
![]() |