What is the required density for a warehouse with 10 ft (3 m) deep multiple-row racks without an in-rack sprinkler

system that contains a nonencapsulated storing Class IlI commodity on wooden pallets and has a storage height of

18 ft (5.4 m) and 8 ft (2.4 m) aisles, and is using standard, ordinary temperature sprinkler heads?

Options:
A.

0.25 gpm/ft2 (10.2 mm/min)

B.

0.33 gpm/ft2 (13 mm/min)

C.

0.44 gpm/ft2 (17.9 mm/min)

D.

0.52 gpm/ft2 (20.8 mm/min)

NFPA CWBSP Premium Access
Questions 2

What piping material is acceptable for the suction and discharge piping pressure maintenance pumps?

Options:
A.

Copper tube

B.

Black or galvanized steel piping

C.

Listed CPVC piping

D.

HDPE piping

Questions 3

Which of the following should be considered when choosing an occupancy?

Options:
A.

Size of space

B.

Susceptibility for change in fuel characteristics

C.

Ceiling height to underside of structural members

D.

Access to egress

Questions 4

According to NFPA 13, for a high rise building sprinklered throughout, that has four stairwells, each with a standpipe and hose valves, and has a Class I standpipe system, what is the maximum flow rate required to be calculated?

Options:
A.

750 gpm (2,840 L/min)

B.

1,000 gpm (3,785 L/min)

C.

1,250 gpm (4,731 L/min)

D.

1,500 gpm (5,678 L/min)

Questions 5

What is the minimum flow rate required for the most hydraulically remote Class I standpipe?

Options:
A.

250 gpm (946 L/min)

B.

500 gpm (1893 L/min)

C.

750 gpm (2840 L/min)

D.

1,000 gpm (3785 L/min)

Questions 6

When used for sprinkler system design, the water flow test shall be conducted no more than how many months prior

to work plan submittal?

Options:
A.

3

B.

6

C.

12

D.

18

Questions 7

The purpose of the owner's certificate is to

Options:
A.

help ensure that the capability of the sprinkler system is adequate to address the hazard.

B.

replace project plans.

C.

obtain the building permit.

D.

be a declaration by the sprinkler contractor as to the hazards in the building.

Questions 8

What is the maximum allowable water delivery time for a dry pipe system protecting an Ordinary Hazard Group II occupancy?

Options:
A.

40 seconds

B.

45 seconds

C.

50 seconds

D.

60 seconds

Questions 9

After reviewing an existing sprinkler system, it was determined that sprinklers were installed using NFPA 13 using the Ordinary Hazard Pipe Schedule method. The highest elevation of sprinklers is 28 ft (8.53m) and the system is fully monitored as specified by NFPA 13. What is the minimum pressure and flow required?

Options:
A.

500 gpm at 27 psi (1,900 L/min at 1.86 bar)

B.

850 gpm at 27 psi (3,200 L/min at 1.86 bar)

C.

500 gpm at 32 psi (1,900 L/min at 2.2 bar)

D.

850 gpm at 32 psi (3,200 L/min at 2.2 bar)

Questions 10

For an existing antifreeze system without a backflow prevention device, what size hole is required in the check valve separating the supply and the antifreeze?

Options:
A.

1/32 in. (0.79 mm)

B.

1/16 in. (1.59 mm)

C.

1/8 in.(3.17 mm)

D.

1/4 in. (6.35 mm)

Exam Code: CWBSP
Certification Provider: NFPA
Exam Name: Certified Water-Based Systems Professionals
Last Update: Jul 19, 2025
Questions: 100
PDF + Testing Engine
$164.99
$57.75
Testing Engine
$124.99
$43.75
PDF (Q&A)
$104.99
$36.75

NFPA Free Exams

NFPA Free Exams
Enhance your NFPA exam prep with free resources and practice tests from Examstrack. Achieve NFPA certification success by exploring Examstrack.