Big Halloween Sale 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: sale65best

Free Huawei H13-624_V5.5 Practice Exam with Questions & Answers | Set: 3

Questions 21

When demarcating a performance issue of Huawei flash storage, engineer A finds that the latency observed on the compute side is much longer than that on the storage side. This indicates that the issue most possibly occurred on the storage, for example, the disk performance upper limit has been reached.

Options:
A.

TRUE

B.

FALSE

Huawei H13-624_V5.5 Premium Access
Questions 22

To analyze disk performance, we can first use tools (such as free, top, vmstat, and pidstat) that support many indicators, and then determine the I/O source and analyze the file system and process I/Os.

Options:
A.

TRUE

B.

FALSE

Questions 23

Routine management on Huawei flash storage systems involves power-on and power-off. Which of the following statements is false about power-on and power-off?

Options:
A.

Before powering on the storage system, you need to ensure that all expansion cables are correctly connected. The storage system may work improperly if the connection mode of expansion cables is adjusted after the storage system is powered on.

B.

If none of the controller enclosures in the cluster are powered on, you can log in to the BMC system using the external management IP address of the BMC and run the power-on command to power on all the controller enclosures.

C.

To power on the storage system after an emergency power-off, you need to press the power button on the controller enclosure.

D.

For Huawei OceanStor Dorado 8000 storage, after a controller enclosure is powered on, its cascaded disk enclosures will be automatically powered on.

Questions 24

Which statements are false about software Installation of Huawei OceanStor Pacific series storage systems?

Options:
A.

To install the Distributed Parallel Client (DPC), the switch configuration is required before the installation regardless of whether the low level design (LLD)- or wizard-based installation mode is selected.

B.

To interconnect with FusionCompute during block service installation, storage and compute nodes must be deployed in converged mode, and the management nodes must be deployed in the virtualization environment.

C.

To interconnect with Huawei Cloud Stack during block service installation, storage and compute nodes must be deployed in converged mode, and the management nodes must be deployed in the virtualization environment.

D.

To install the file service in the standard protocol scenario, the switch configuration is not required throughout the entire installation process.

Questions 25

For device reliability purposes, during the quick Installation of OceanStor Pacific 9550, engineers need to connect power cables on the storage device supplied by two power modules to separate power distribution units (PDUs).

Options:
A.

TRUE

B.

FALSE

Questions 26

When delivering a Huawel OceanStor Pacific scale-out storage project, an engineer introduced the end-to-end data Integrity check technology of scale-out storage to the customer. Which of the following statements are false about this technology?

Options:
A.

This technology enables the storage system to implement periodic background data integrity check. When the service load is heavy or service access is frequent, the system automatically starts periodic background data integrity check and self-healing.

B.

For silent data scenarios such as bit change and read offset, the end-to-end data integrity check technology supports logical block addressing (LBA) check of clusters and hosts.

C.

Block, NAS, and object services support end-to-end data integrity check, but the HDF5 service does not.

D.

In this technology, write requests are checked at the system entry (virtual block service). User data is checked again in the object storage device (OSD) before being written to disks. Data Is written to disks only after the data integrity check succeeds.

Questions 27

The backup and archiving scenario mainly involves sequential read of large I/Os, where there are more read I/Os than write I/Os and hot data areas are obvious. The service characteristics of this scenario are the same as those of the database OLAP scenario.

Options:
A.

TRUE

B.

FALSE

Questions 28

An industry customer purchases several Huawei flash storage devices for service deployment. During routine management, an engineer finds that a controller of one device is faulty, but the fault is common, so the engineer does not need to perform emergency handling.

Options:
A.

TRUE

B.

FALSE

Questions 29

When delivering a Huawei OceanStor Pacific storage project, a Huawei engineer vigorously promoted the SmartEncryption feature of scale-out storage to customers. Which of the following statements is false about this feature?

Options:
A.

When the data is read using the DPC or NFS protocol, the SED obtains the identity authentication key from the key management server, reads and decrypts the ciphertext data, and then returns the plaintext data to the protocol layer. The protocol layer returns the plaintext data to client applications.

B.

This feature supports encrypted data write using NFS, CIFS, HDFS, or S3. Data is decrypted and read using NFS, CIFS, HDFS, or S3.

C.

The file service client can write plaintext data through the NFS/CIFS/DPC protocol.

D.

Huawei OceanStor Pacific series scale-out storage supports disk encryption. All data delivered by services is stored on self-encrypting disks (SEDs).

Questions 30

An industry customer has purchased a Huawei OceanStor Pacific scale-out storage system for service deployment. An engineer configures NFS file sharing on the storage system through NFSv4.0. Which of the following commands can the engineer use to switch the user view to the developer view on the command line interface (CLI)?

Options:
A.

change domain ad_manager operation=develop

B.

change dns general address=develop

C.

change user_mode current_mode user_mode=developer

D.

change nas_Idap advanced_config