A potential customer is considering replacing a four year old, Linux-based NFS server with 40TB of usable capacity. The existing system supports home directories, an internal website, and a content repository for the customer's content management system. The customer is concerned about performance of any new solution because they expect to double workload in the content management system.
What tools can be used to collect performance data needed to size the new solution?
Which tool is used to perform a cluster-wide kernel configuration change on an Isilon Gen 6 cluster?
Your customer has an Isilon Gen 6 cluster with eight H400 nodes. During an unexpected power outage some
of the nodes go offline simultaneously.
How many nodes need to remain up and communicating over the backend network to maintain a quorum in
the cluster and still enable write access to the OneFS file system?
A customer has grown 2 PB in the last year. The cluster performs well most times of the day, but occasionally during the day, the customer notices a decrease in performance. You have been told that ‘tree-deletes’ are taking too long and can only be run on weekends.
What would you recommend to speed up the ‘tree-deletes’?
You have had several meetings with an existing EMC VMAX customer. They have agreed that they would like to review an initial Isilon Solution for unstructured data used by the Product Development Team. All production is managed through a Global Enterprise Resource Planning system based in Germany. They require 600TiB of usable capacity. The File System must be accessible from Windows and Linux High-End Workstations. The files are generally not accessed after 120 days, and they would like automated tiering.
Which questions about architectural integration will impact the solution design?
A customer has a supported cluster with the maximum protection level. How many simultaneous node component failures can Isilon OneFS sustain while still allowing full access to the entire file system and dataset?
What is the correct sequence of events in a SyncIQ failover procedure after a failure occurs in the source Isilon cluster?
When using an N+2:1 protection policy on a 7-node Isilon cluster, how much capacity will be used to store a 510 KiB file?
An Isilon has 6 X410 nodes and 4 NL410 nodes. How many job engine directors does the cluster have?
A Media and Entertainment company is considering changing from 2K resolution to 4K resolution. They will continue to use the DNxHD 220 codec.
Assuming everything else stays the same, how will this change affect storage?
PDF + Testing Engine
|
---|
$66 |
Testing Engine
|
---|
$50 |
PDF (Q&A)
|
---|
$42 |
EMC Free Exams |
---|
![]() |