New Year Special 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: bestdeal

Free EMC E20-526 Practice Exam with Questions & Answers

Questions 1

A physical XtremIO Management Server (XMS) has failed and requires replacement. Which two software packages are required for recovery?

Options:
A.

XMS image and OVA image

B.

Xtremapp and OVA image

C.

XMS image and Xtremapp

D.

Xtremapp and MPIO

EMC E20-526 Premium Access
Questions 2

You are designing an XtremIO solution for a potential customer. If the server and storage information is available, which information should be documented regarding the customer’s capacity expectations?

Options:
A.

Capacity requirements on a per data center basis

Expandability/scalability

Performance requirements determined on a server-to-server basis

B.

Capacity requirements on a per volume basis

Expandability/scalability

Performance requirements determined on a server-to-server basis

C.

Capacity requirements on a per volume basis

Compression rates/scalability

Performance requirements determined on a server-to-server basis

D.

Capacity requirements on a per data center basis

Expandability/scalability

Performance requirements determined holistically

Questions 3

How should a storage administrator navigate to different XtremIO clusters from the XMS GUI if the administrator has more than one cluster managed by the same XMS?

Options:
A.

Click the Cluster Name on the Menu bar near the top of the screen

B.

Click the Inventory List button on the Menu bar

C.

Click the Administration tab and locate the Cluster Name

D.

Click the Cluster Name on the Status bar at the bottom of the screen

Questions 4

A storage administrator has 20 TB of storage provisioned to their ESXi cluster from a 10 TB XtremIO storage array. The administrator is concerned about running out of physical capacity on the XtremIO.

Which recommendation will assist the administrator?

Options:
A.

Enable VAAI TPSTUN

B.

Increase the compression ratio on the XtremIO

C.

Disable VAAI XCOPY

D.

Thick provisioned eager zero all VM virtual disks

Questions 5

A user attempts to create a quorum disk for a host cluster. Volume parameters are:

  • Size = 1000 kB
  • Name 1MB_Vol

However, the volume creation fails. What caused the process to fail?

Options:
A.

Quorum disks cannot have an 8kB block size

B.

Volume size is too small

C.

Volume name is invalid

D.

XtremIO volumes cannot be quorum disks

Questions 6

Which actions are initiated when a snapshot is created on an XtremIO array?

Options:
A.

Parent object becomes read only and two auxiliary volumes are created

B.

Parent object remains writeable and one auxiliary volume is created

C.

Parent object remains writeable and two auxiliary volumes are created

D.

Parent object becomes read only and one auxiliary volume is created

Questions 7

You have been asked to design an XtremIO storage array solution that will be used for two large applications workloads. One overload will generate approximately 150,000 write IOPs with an average 4 kB I/O size. The second write workload will have an average I/O size of 128 kB and will generate approximately 2 GB/s of throughput.

At a minimum, how many X-Bricks are needed in a single cluster to meet this requirement?

Options:
A.

2

B.

4

C.

6

D.

8

Questions 8

A customer has a VMware vSphere environment running Native Multipathing (NMP). Which path selection policy should be set for optimal performance when connected to an XtremIO cluster?

Options:
A.

Fixed AP

B.

Most Recently Used

C.

Fixed

D.

Round Robin

Questions 9

You need to design a VDI solution for a customer. Which best practices should be used for VDI environments?

Options:
A.

Align data on 4 kB boundaries. Put persona and user data on XtremIO LUNs

B.

Align data on 4 kB boundaries. Allocate multiple XtremIO LUNs to each host

C.

Align data on 8 kB boundaries. Put the master VM image on an XtremIO LUN

D.

Align data on 8 kB boundaries. Put all VDI-related data on one large LUN

Questions 10

What is the maximum speed of the Fibre Channel ports on an XtremIO storage controller?

Options:
A.

2 Gb/s

B.

4 Gb/s

C.

8 Gb/s

D.

16 Gb/s

Exam Code: E20-526
Certification Provider: EMC
Exam Name: XtremIO Solutions and Design Specialist Exam for Technology Architects
Last Update: Mar 27, 2025
Questions: 67
PDF + Testing Engine
$164.99
$66
Testing Engine
$124.99
$50
PDF (Q&A)
$104.99
$42