Summer Special 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: bestdeal

Free EMC D-PWF-DS-23 Practice Exam with Questions & Answers

Questions 1

An administrator wants to configure SDTs to perform I/O with hosts that are going to use the NVMe over Fabric protocol What are three requirements to accomplish this task (Select 3)

Options:
A.

The Storage port must be configured with the host role

B.

The Discovery port must be configured with the storage role

C.

The NVMe Qualified Name of the hosts is known

D.

A minimum of two NVMe targets must be assigned to a Protection Domain.

E.

The storage rote and hosts role must be configured to the same target IP addresses

EMC D-PWF-DS-23 Premium Access
Questions 2

Which component of the PowerFlex cluster provides server metrics such as telemetry thermal data and sets the server configuration profile?

Options:
A.

PowerFlex Manager

B.

CloudLink Center

C.

VMware ESXi

D.

iDRAC

Questions 3

An administrator wants to track total usage on a PowerFlex File system but does not want to impose any restrictions on their users How can this be accomplished using quotas'?

Options:
A.

Create a usei quota and set an indefinite grace period

B.

Create a user quota and set both the soft and hard limits to zero

C.

Create a tree quota and set an indefinite grace period

D.

Create a tree quota and set both the soft and hard limits lo zero

Questions 4

D-PWF-DS-23 Question 4

A customer recently expanded their PowerRex rack solution from two cabinets to five cabinets What should be done to optimize redundancy of the MDM roles?

Options:
A.

Move MDM 3 Tie-breaker Land Tie-breaker 2 to separate cabinets

B.

Add Standby MDMs to Cabinet 3 Cabinet 4 and Cabinet 5.

C.

Change the MDM Cluster Mode from three-node to five-node

D.

Consolidate MDM 2 and Tie-breaker 1 into Cabinet 1

Questions 5

What is the correct sequence of steps to create an FG Storage Pool within a PowerFlex system?

D-PWF-DS-23 Question 5

Options:
Questions 6

Which PowerFlex offering is a fully engineered system that comes with licensing and a unified management platform?

Options:
A.

PowerFlex custom node

B.

PowerFlex appliance

C.

PowerFlex rack

D.

PowerFlex software only

Questions 7

Place the steps to set up remote replication on the Powerflex system in the correct order

D-PWF-DS-23 Question 7

Options:
Questions 8

A customer is adding more storage (o their system that requires compression Which two components are required? (Select 2)

Options:
A.

At least two NVDIMMs in each server

B.

Fine Granularity Storage Pool

C.

Medium Granularity Storage Pool

D.

At least two NVMe disks in each server

E.

At least two SSD disks in each server

Questions 9

What maximum raw capacity can a user expect in a 1U Node while configuring a PowerFlex with an MG pool?

Options:
A.

38 4 TB

B.

307.2 TB

C.

76.8 TB

D.

153.6 TB

Questions 10

Where must a customer go to generate a software troubleshooting bundle?

Options:
A.

PowerFlex Manager Events and Alerts

B.

PowerFlex Manager Serviceability

C.

iDRAC Lrfecycle Controller

D.

CloudLmk Center Console