Month End Special 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: sale65best

Master the BICSI RCDD-002 Exam: Essential Study Tips and Strategies

Questions 11

You are designing a nurse call system for a health care facility. The system will have emergency call switches. What is the first step you should take in designing the nurse call system?

Options:
A.

Properly size the supporting TR to accommodate the headend system

B.

Program the headend device for the various call switches that will be used

C.

Perform a risk assessment to determine call switch locations

D.

Perform a site survey to verify the pathways that will connect the headend device with the call switches

BICSI RCDD-002 Premium Access
Questions 12

How much area of wall space is needed in the telecommunications room (TR) to support a nurse call system?

Options:
A.

1.2m x 1.2 m (4 ft x 4 ft)

B.

1.2m x 2.4 m (4 ft x 8 ft)

C.

2.4 m x 2.4 m (8 ft x 8 ft)

D.

2.4 m x 3.6 m (8 ft x 12 ft)

Questions 13

You are designing an interactive patient television system (IPTS) that will provide internet, nurse call and LCD television services. From the following, which medium will NOT support these services in a backbone cabling system?

Options:
A.

Balanced twisted pair

B.

Coaxial 1/2 inch hard-line cable

C.

Multimode optical fiber cable

D.

RG-11 coaxial cable

Questions 14

Which of the following is an alarm management output system?

Options:
A.

Patient monitoring system

B.

Bed monitoring system

C.

Security system

D.

Wireless telephone system

Questions 15

You are renovating telecommunication rooms that support an acute care facility that has 10,000 sq ft floors. The facility will be adding 15,000 sq ft to each of the floors. What is the MINIMUM additional floor space that you will need to expand the TRs to support the new floor space?

Options:
A.

3 m x 3 m (10 ft x 10 ft)

B.

3.5 m x 4.3 m (11.5 ft x 14 ft)

C.

3.0 m x 4.5 m (10 ft x 15 ft)

D.

6 m x 6 m (20 ft x 20 ft)

Questions 16

Exhibit:

RCDD-002 Question 16

What does this international symbol stands for?

Options:
A.

Teletypewriter/text telephone

B.

Public internet station

C.

Public telephone

D.

Public telephone with a shelfette

E.

Public telephone with access to high-speed internet connection

Questions 17

Exhibit:

RCDD-002 Question 17

In this future marina layout, assuming that there are fewer than 10 slips being cabled, what would be the pre-cabling guideline to follow for terminal A?

Options:
A.

Installed one or two pair cables from the boat slips to a distribution terminal on the closest point of land.

B.

Place distribution cable onto the dock and terminate in a suitable cabinet or enclosure. Install service drop to each boat slip.

C.

Pre-cable each boat slip during construction.

D.

For security, each install should be terminated in the patch panel/cross-connect at the dockmaster or marina office.

Questions 18

Which type of protection for electrical power stations provide isolation against a rise in potential of station ground and also provide drainage protection against longitudinally-induced voltages?

Options:
A.

Isolating transformers

B.

Neutralizing transformers

C.

Mutual drainage reactors

D.

Unit-type neutralizing transformers

E.

2-winding neutralizing transformers

Questions 19

What is the MINIMUM distance from the edge of a pool or other water hazards for a weatherproof enclosure?

Options:
A.

1 m (3 ft)

B.

2 m (7 ft)

C.

4 m (13 ft)

D.

6 m (20 ft)

E.

10 m (30 ft)

Questions 20

What is the air change requirement for a tunnel of 610 m (2000 ft) long with a diameter of 3.4 m (11 ft)?

Options:
A.

One complete air change per hour

B.

Two complete air changes per hour

C.

Three complete air changes per hour

D.

Four complete air changes per hour

E.

Five complete air changes per hour