Summer Special 60% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: bestdeal

Achieve Success in the EMC E20-375 Exam: A Detailed RecoverPoint Specialist Exam for Implementation Engineers Guide

Questions 1

What is a benefit of integrating RecoverPoint with VMware Site Recovery Manager (SRM)?

Options:

A.

Enables coordinated failover of virtual machines and their storage

B.

Eliminates hardware dependencies when using heterogeneous storage with VMware

C.

Enables replication of individual virtual machines without the need to replicate an entire VMFS volume

D.

Enables full protection of VMware ESXi servers

Buy Now
Questions 2

A VPLEX write splitter can be shared with how many RecoverPoint clusters?

Options:

A.

5

B.

6

C.

8

D.

10

Buy Now
Questions 3

Which Unisphere for RecoverPoint view displays both the system traffic and Consistency Group status?

Options:

A.

RecoverPoint Dashboard

B.

Recovery

C.

RPA Clusters

D.

Admin

Buy Now
Questions 4

You are adding a new vRPA to a cluster using the Add New RPAs wizard in Deployment Manager. SAN diagnostics fail and you cannot add the RPA. Pings to the vRPA and VNX iSCSI ports are returned successfully.

What is most likely the cause for this connection problem?

Options:

A.

CHAP authentication not correct

B.

vRPA iSCSI ports MTU set to a number lower than 9000

C.

Default gateway setting for RPA iSCSI ports not correct

D.

Wrong IP version set on vRPA iSCSI ports

Buy Now
Questions 5

A company with a DR site connected with a 2 Gbps FC link has three vRPAs at each site. They are experiencing High Load events, although the FC link is not fully utilized.

What would be the best solution to get the FC link utilization up as high as possible while mitigating those events?

Options:

A.

Replace the vRPAs with physical RPAs and start using a Distributed Consistency Group

B.

Add two more vRPAs to the Primary site and divide the Consistency Group into four segments

C.

Divide the Consistency Group into two segments and start using Distributed Consistency Groups

D.

Add two RPAs to the Primary site as well as the secondary site

Buy Now
Questions 6

You are creating a Consistency Group with the Protect Volumes wizard in a RecoverPoint/EX environment.

What LUNs are displayed in the list generated by the wizard?

Options:

A.

LUNs masked to the RPAs

B.

LUNs configured on the licensed array

C.

LUNs attached to the splitter

D.

LUNs masked to the production host

Buy Now
Questions 7

A customer is installing a single cluster RecoverPoint/SE environment and has decided to create a cluster of six virtual RPAs to perform RecoverPoint operations.

According to EMC best practices, how many ESX hosts are needed to host the required vRPAs?

Options:

A.

2

B.

3

C.

4

D.

6

Buy Now
Questions 8

A RecoverPoint/SE cluster is using vRPAs. A second cluster needs to be connected. Which RPA type must be used at the new cluster?

Options:

A.

Virtual or Physical

B.

Virtual only

C.

Generation 5

D.

Physical only

Buy Now
Questions 9

A customer has a four-node RecoverPoint cluster using a VNX array. All LUNs are replicating and failover has been tested. The customer would like to integrate RecoverPoint and Unisphere. However, they are unable to manage the cluster through Unisphere.

What should the customer do to correct the issue?

Options:

A.

Convert to RecoverPoint/SE using Deployment Manager

B.

Reinstall the RecoverPoint splitter enabler on the VNX

C.

Rescan the VNX splitters in the management application

D.

Reinstall the RecoverPoint/SE license file

Buy Now
Questions 10

A customer environment includes a two-cluster RecoverPoint/SE instance. They have a new data center 500 km away that they wish to protect with RecoverPoint.

What steps are required to connect a new cluster to their existing RecoverPoint instance?

Options:

A.

Use Deployment Manager to convert the existing instance to RP/EX.

Use Deployment Manager to connect the new cluster to the existing instance.

Install RP/EX licenses for their existing arrays.

B.

Use Deployment Manager to connect the new cluster to the existing instance.

C.

Install RP/SE licenses for their existing arrays.

Install RP/SE licenses for the new cluster.

Use Deployment Manager to connect the new cluster to the existing instance.

D.

Install RP/CL licenses for their existing cluster.

Use Deployment Manager to connect the new cluster to the existing instance.

Buy Now
Exam Code: E20-375
Exam Name: RecoverPoint Specialist Exam for Implementation Engineers
Last Update: Jun 23, 2024
Questions: 200

PDF + Testing Engine

$159.99
$64

Testing Engine

$119.99
$48

PDF (Q&A)

$99.99
$40