Questions 11

When using Surface Automation Blue Prism is required to read the text contained within the Notes field below:

APD01 Question 11

To do this, the field must be highlighted and the Keystrokes CTRL & C must be sent to the application to copy the text to the clipboard.

The Note Box has been identified as a Region within the following Application Model.

APD01 Question 11

Assuming all the text in the Notes field has been successfully highlighted, which of the following stages will successfully send CTRL & C to the application to copy the highlighted text to the Clipboard?

APD01 Question 11

APD01 Question 11

APD01 Question 11

APD01 Question 11

Options:

A.

Option A

B.

Option B

C.

Option C

D.

Option D

Buy Now
Questions 12

The following sub-page in a process creates an order in an order system.

APD01 Question 12

The Actions called perform the following steps:

Navigate to New Order – The application is navigated to a new order screen. There is a wait stage to confirm the navigation is successful – if this wait stage times out, an exception is configured which will bubble up to this page.

Enter Order Details – The Order details are entered triggering a ‘Confirm Order’ window. At this page, the order has not been submitted. There is a wait stage to confirm the ‘Confirm Order’ window has appeared – if this stage times out, an exception is configured which will bubble up to this page.

Submit Order – The order is confirmed and placed in the Client’s order system. There is a wait stage, for a reference number, configured that the order has been successfully submitted. If this wait stage times out, an exception is configured which will bubble up to this page. There is a known bug in the application which results in the application occasionally freezing when an order is submitted but before the reference number is displayed, thus leaving the user uncertain if the order has been successfully submitted or not.

Get Reference Number – A resultant reference number is read from the application.

In order to build some resilience into the process, some retry logic is to be added. Which of the below options offers the best retry solution?

A)

APD01 Question 12

B)

APD01 Question 12

C)

APD01 Question 12

D)

APD01 Question 12

Options:

A.

Exhibit A

B.

Exhibit B

C.

Exhibit C

D.

Exhibit D

Buy Now
Questions 13

Which of the following is an alternative to the usual method of spying application elements when spying issues are encountered?

Options:

A.

Application Model

B.

Application Navigator

C.

Highlight

D.

System Navigator

Buy Now
Questions 14

Which of the following statements regarding Blue Prism Login Agent are true? (Select all that apply.)

Options:

A.

Windows passwords can be changed using Login Agent Functionality

B.

It is not possible to use Login Agent to traverse the ‘Press CTRL + ALT + DELETE to log on’ screen

C.

Blue Prism Login Agent can be used to lock a Resource PC

D.

You cannot configure the Blue Prism scheduler to login via Login Agent and then run a business process once it has logged in

Buy Now
Questions 15

Which of the following statements about the status of a work queue is/are correct?

1. The status can be used as a method of recording what work has been done so far on a Work Queue item

2. The status is set using the Update Status action of the Work Queues business object

3. Every time the Update Status action is executed, the existing status is appended. Each status is separated with a semi colon.

4. The status can be used to aid manual working of exceptions; providing the Item Status can inform staff what work is still outstanding on an item that needs manually completing

Options:

A.

1, 2, 3 and 4

B.

1, 2 and 4

C.

1, 2 and 3

D.

1 only

Buy Now